$1

Dual Input Meter The accuracy of all measurements is within ±(% of reading + number of counts) fro

Quantity
Add to wish list
Product description



  Dual Input Meter

  The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.

  Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen.

  Input A and input B - DC voltage (VDC)

  Ranges

  500 mV, 5 V, 50 V, 500 V, 750 V.

  Accuracy

  ±(0.5% +5 counts).

  Common mode rejection (CMRR)

  >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz.

  Full scale reading

  5000 counts.

  True-rms voltages (V ac and V ac+dc)

  Ranges

  500 mV, 5 V, 50 V, 500 V, 750 V.

  Accuracy for 5% to 100% of range (DC coupled)

  DC to 60 Hz (V ac+dc) - ±(1% +10 counts)

  1 Hz to 60 Hz (V ac) - ±(1% +10 counts).

  Accuracy for 5% to 100% of range (AC or dc coupled)

  60 Hz to 20 kHz - ±(2.5% +15 counts).

  DC rejection (only VAC)

  >50 dB.

  Common mode rejection (CMRR)

  >100 dB @ dc

  >60 dB @ 50, 60, or 400 Hz.

  Full scale reading

  5000 counts, reading is independent of any signal crest factor.

  Peak

  Modes

  Max peak, Min peak, or pk-to-pk.

  Ranges

  500 mV, 5 V, 50 V, 500 V, 2200 V.

  Accuracy

  Accuracy Max peak or Min peak: 5% of full scale

  Accuracy Peak-to-Peak: 10% of full scale.

  Full scale reading

  500 counts.

  Frequency (Hz)

  Ranges

  123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz.

  Frequency range

  15 Hz (1 Hz) to 50 MHz in continuous autoset.

  Accuracy @1 Hz to 1 MHz

  ±(0.5% +2 counts).

  Full scale reading

  10,000 counts.

  RPM

  Max reading

  50.00 kRPM.

  Accuracy

  ±(0.5% +2 counts).

  Duty cycle (PULSE)

  Range

  2% to 98%.

  Frequency range

  15 Hz (1 Hz) to 30 MHz in continuous autoset.

  Pulse width (PULSE)

  Frequency range

  15 Hz (1 Hz) to 30 MHz in continuous autoset.

  Full scale reading

  1000 counts.

  Amperes (AMP)

  With current clamp

  Ranges: Same as V dc, V ac, V ac+dc, or PEAK

  Scale factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA.

  Temperature (TEMP) with optional temperature probe

  Range

  200 °C/div (200 °F/div).

  Scale factor

  1 mV/°C and 1 mV/°F.

  Accuracy

  As V dc (add temp. probe uncertainty).

  Decibel (dB)

  0 dBV

  1 V.

  0 dBm (600 Ω /50 Ω)

  1 mW referenced to 600 Ω or 50 Ω.

  dB on

  V dc, V ac, or Vac+dc.

  Full scale reading

  1000 counts.

  Crest factor (CREST)

  Range

  1 to 10.

  Full scale reading

  90 Counts.

  Phase

  Modes

  A to B, B to A.

  Range

  0 to 359 degrees.

  Resolution

  1 degree.

  Miscellaneous

  Display

  5.7-inch color active matrix TFT

  640 x 480 pixels.

  Waveform Display

  Vertical: 10 div of 40 pixels

  Horizontal: 12 div of 40 pixels.

  Power

  External: Via Power Adapter BC430

  Input voltage: 10 V DC to 21 V DC

  Power consumption: 5 W typical

  Input connector: 5 mm jack

  Internal: Via Battery Pack BP290

  Battery power: Rechargeable Li-Ion 10.8 V

  Operating time: 7 hours with 50% backlight brightness

  Charging time: 4 hours with test tool off, 7 hours with test tool on

  Allowable ambient temp: 0 to 40 °C (32 to 104 °F) during charging.

  Memory

  Internal memory can store 20 data sets (screen waveform and setup).

  Interface

  Optically isolated: Transfer screen copies (bitmaps), settings and data

  USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®..

  Dimensions

  259 x 132 x 55 mm (10.2 x 5.2 x 2.15 in).

  Weight

  1.4 kg (3.2 lb) including battery pack.

  Fluke 123B warranty

  3 years.

Related products